A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the EXTECH INSTRUMENTS EX570 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   EXTECH INSTRUMENTS EX570   Description / Specification:    
EXTECH INSTRUMENTS EX570 True RMS Autoranging Multimeter with IR Thermometer

The Extech EX570 Industrial Multimeter with built-in infrared thermometer delivers every multimeter function you need, along with high accuracy and True RMS precision. It is designed to withstand harsh environments and usage with a rugged, double-molded housing. The large, illuminated LCD displays a five-digit readout (to 40,000 counts) and a useful 40-segment bar graph for analog comparisons and quick “needle-swing” tests. The EX570 offers a wide array of must-have multimeter measurements including capacitance, frequency, diode, continuity functions, plus convenient, one-button access to frequently used functions: Min/Max, Average, Hold, Relative, and Peak Hold, as well as selectable auto-ranging or manual-ranging.
Specifications.

Display Counts: 40,000 count.
Basic Accuracy: 0.06%.
DC/AC Voltage: 0.01mV to 1000VDC ; 0.1mV to 1000VAC.
DC/AC Current: 0.01μA to 20A.
Resistance: 0.01Ωto 40MΩ.
Capacitance: 0.001nF to 10,000μF.
Frequency: 0.0001Hz to 40MHz.
IR Temperature (301 ratio): -22 to 1022°F (-30 to 550°C).
Temperature (Type K): -50 to 1382°F (-45 to 750°C).
Duty Cycle: 0.01 to 99.99%.
Diode/Continuity: Yes.
Maximum Voltage AC: 1000 V.
Resolution AC Volts: 0.01 mV.
Maximum Voltage DC: 1000 V.
Resolution DC Volts: 0.01 mV.
Maximum Current AC: 20 A.
Minimum Current AC: 0.01 uA (0.00001 mA).
Resolution AC Current: 0.01 uA (0.00001 mA).
Maximum Current DC: 20 A.
Minimum Current DC: 0.01 uA (0.00001 mA).
Resolution DC Current: 0.01 uA (0.00001 mA).
Basic Accuracy V DC: .06%.



 



Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBc
dBc (decibels relative to the carrier) is the power ratio of a signal to a carrier signal, expressed in decibels. If the dBc figure is positive, then the relative signal strength is greater than the carrier signal strength. If the dBc figure is negative, then the relative signal strength is less than carrier signal strength.

Load Regulation
Load regulation is the capability to maintain a constant voltage (or current) level on the output channel of a power supply despite changes in the supply's load (such as a change in resistance value connected across the supply output).

Power Linearity
When changing the power level and measuring the differences (in dB) between actual and displayed power levels, the power linearity is ± half the span (in dB) between the maximum and the minimum value of all differences.

Settling Time
Settling time of an output device is the time elapsed from the application of an ideal instantaneous step input to the time at which the amplifier output has entered and remained within a specified error band, usually symmetrical about the final value.


Please contact us for your EXTECH INSTRUMENTS EX570 CALIBRATION and/or EXTECH INSTRUMENTS EX570 True RMS Autoranging Multimeter with IR Thermometer REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: